PRODUCTS
CENTRIFUGAL FANS
Mirolli Srl designs and manufactures centrifugal fans in accordance with international standards for the Oil & Gas, chemical and petrochemical fields.
Centrifugal fans are selected, designed and manufactured as required by customer specifications and international standards.
Mirolli Srl offers a range of fans for low, medium and high pressures.
The fans can reach flow rates up to 600,000 m3/h and pressures up to 30,000 Pa.
In order to ensure maximum durability, we offer Heavy Duty fans that are designed to operate in any type of environment. The materials are defined in the design phase considering the environmental conditions of the site and the process factors.
DAMPERS
Mirolli Srl boasts experience in the design and construction of:
• Single and multi-blade valves for low temperatures
• Single and multi-blade valves for high temperatures with internal refractory lining
• Dampers with parallel or opposite blades
• Inlet guide vane
These products are designed and customized as required by project specifications and international standards
DUCTS
Mirolli Srl in recent years has designed and manufactured large ducts for the Oil & Gas, petrochemical and fertilizer fields.
The ducts have been designed in accordance with the main international standards (ASME, EN, API) with diameters up to 5500 mm and sections of 5200 x 4800 mm.
Mirolli Srl is able to offer design and construction within its factories.
FREE-STANDING CHIMNEYS AND AIR INTAKE
Mirolli Srl specializes in the construction of free-standing chimneys and air intakes.
Air intakes are designed and manufactured in accordance with API 560 and API 673 technical standards as ventilation accessories. Solutions with sand trap or filter cells can also be supplied.
Mirolli Srl is ISO 13084-7 certified for the design and construction of steel free-standing chimneys.
The materials used for the construction of them are carbon steel S235JR / S275JR / S355J2 or stainless steel AISI 304, AISI 316.
The coatings are also designed for aggressive environments and defined in accordance with UNI EN ISO 12944.
The acoustic, fluid dynamic and structural dimensions of the fireplaces are defined in accordance with the required standards.
SILENCER
The silencers are designed to reduce the noise level.
They allow the noise level of the fluid to be attenuated so as to reach acceptable levels in civil and industrial environments.
To reduce noise pollution Mirolli Srl offers two series of silencers:
Circular Silencers
There are two constructive versions, silencers with ogive and without ogive
The first version has a better attenuation capacity as they have a greater sound-absorbing surface than the version without ogive.
They are made with an external casing in galvanized or painted sheet metal flanged at the ends.
The materials can be defined according to the specific requests from the customer.
Rectangular silencers
They are made with an external casing in galvanized or painted sheet metal flanged at the ends.
The sound-absorbing partitions consist of a galvanized sheet frame with mineral wool inside, protected by fiberglass and galvanized perforated metal-mesh.
The materials can be defined according to the specific requests from the customer.